Repair Wsa Error 10055 (Solved)

Home > Socket Error > Wsa Error 10055

Wsa Error 10055

Contents

The error is translated from the Winsock error code WSAENOBUFS, 10055. Results 1 to 1 of 1 Thread: WSA error 10055 ??? Could that be something to do with this problem? 0 Message Author Comment by:OldVB62011-06-08 The data received is of varying lengths, the code always retrieves all data in the buffer. The connection has been broken due to keep-alive activity detecting a failure while the operation was in progress.

Check that no old Windows Sockets DLL files are being accessed. How should I troubleshoot? A request to send or receive data was disallowed because the socket had already been shut down in that direction with a previous shutdown call. WSAEUSERS 10068 User quota exceeded.

Socket Error 10054

Advanced Search Forum Java Programming Java Programming WSA error 10055 ??? This is usually a temporary error during host name resolution and means that the local server did not receive a response from an authoritative server. windows-server-2003 share|improve this question edited Jun 27 '12 at 14:54 asked Jun 15 '12 at 22:52 Tom Kerr 7617 I'd say that the NIC or driver could contribute to

Close these applications. WSAENAMETOOLONG 10063 Name too long. A QoS error occurred due to lack of resources. Socket Error 10054 Connection Reset By Peer No more results can be returned by the WSALookupServiceNext function.

In the data_arrival procedure as far as I understand it does retrieve all bytes received.. Winsock Error 10053 Basically due to limitations of the hardware I have to maintain a continuous connection with all devices to monitor and control the devices. Client applications usually need not call bind at all—connect chooses an unused port automatically. For instance, if the length of an argument, which is a sockaddr structure, is smaller than the sizeof(sockaddr).

We've noticed that the splunkweb service went down. Socket Error Codes Linux WSA_QOS_NO_RECEIVERS 11008 QoS no receivers. An unrecognized object was found in the QoS provider-specific buffer. Subsequent operations fail with WSAECONNRESET.

Winsock Error 10053

Another possible reason for the WSAEACCES error is that when the bind function is called (on Windows NT 4.0 with SP4 and later), another application, service, or kernel mode driver is bound to WSAEDISCON 10101 Graceful shutdown in progress. Socket Error 10054 The service cannot be found in the specified name space. What Is A Socket Error The requested service provider could not be loaded or initialized.

Not what you were looking for? Ran out of disk quota. The QoS request was rejected because the policy system couldn't allocate the requested resource within the existing policy. Unfortunately, in my a few experiences of Splunk cases, they did not show so many network tcp or udp sessions as output of netstat -an. Socket Error 10049

For example, a socket call requests a SOCK_DGRAM socket, but specifies a stream protocol. This has been identified as the WinRM service responsible for Remote Management. A database query failed because it was actively refused. WSAEFAULT 10014 Bad address.

Is it normal for this to happen? Socket Error 10061 Connection Refused so far i only knew using winsock control. It might also indicate that you are not closing the applications correctly.

This error is returned if either a service provider's DLL could not be loaded (LoadLibrary failed) or the provider's WSPStartup or NSPStartup function failed.

WSAENOBUFS 10055 No buffer space available. I'm guessing VB6 given your moniker. WSASERVICE_NOT_FOUND 10108 Service not found. Winsock Error 10061 I tried it from DOS CLI.

Reply With Quote Jul 21st, 2009,03:29 PM #3 edhanz View Profile View Forum Posts Thread Starter Addicted Member Join Date Aug 2008 Posts 136 Re: Runtime error 10055 - No buffer Thanks gplana and satsumo, great info and advice. Cannot remove a directory that is not empty. They have much larger non-paged pools. –Tom Kerr Jun 23 '12 at 17:44 I would even try Windows 8, as it's possible to upgrade current release to the stable

Yes No Additional feedback? 1500 characters remaining Submit Skip this Thank you! The basic situation is that the other side of the connection says that it has closed the connection due to errors with 10055 as the code. WSA_INVALID_PARAMETER 87 One or more parameters are invalid. I've read that there are lot of literature about this trouble, so I am not the only that suffers from it, but I cannot realise how to solve it, or at

An incorrect number of QoS FILTERSPECs were specified in the FLOWDESCRIPTOR. That they are not trying to use more than one Windows Sockets implementation simultaneously. Does the status update process create new sockets every time? does this have something to do with my hardware?

The item is not available locally. We've reported this to SAP and after running the netstat command, they are claiming that the issue is down to an OS process/service which is taking up a lot of UDP An invalid or inconsistent flowspec was found in the QOS structure. Some error codes defined in the Winsock2.h header file are not returned from any function.